    Home>>HSQ6III series automatic transfer switch automatic switch
    • Industrial control and protection
      • control and protection switch
      • series thermal overload Relay
      • AC contactor
      • motor protector
    • New energy
    • Complete sets of equipment
      • Prefabricated substation
      • Low Voltage Complete-set Switchgear Equipment
      • High Voltage Complete-set Switchgear Equipment
    • Low-voltage distribution
      • Switch Disconnector
      • End Terminal Appliances
      • surge protector
      • automatic transfer switch automatic switch
      • Intelligent instrument
      • Intelligent Type Air Circuit Breaker
      • Moulded Case Circuit Breaker
        • Residual Current Circuit Breaker
        • Thermal Magnetic Moulded Case Circuit Breaker
        • Intelligent Type Moulded Case Circuit Breaker
    • Medium voltage distribution
      • Vacuum circuit breaker
    • Email hsdq@188.com
      • Technical 0571-82699110
      • Sales 0571-82699109
      • Service 0571-82600655

    HSQ6III series automatic transfer switch automatic switch

    Description

    HSQ6III series automatic transfer switch electrical equipment for the PC class three segment automatic transfer switch electrical appliances It is mainly used for ac 50 hz, rated voltage 400 v,rated current to 1600A three-phase four wire power supply network,Because of all the way fault or load required for the power supply automatically or manually switch between to ensure the reliability and security of power supply

    The device has three working positions: “common power supply”, “off position” and “standby power supply”, Has a high ability to turn on and off it can meet with the conventional load conversion, also can satisfy the load conversion with high inductance or large motor, The device is suitable for industrial, commercial, high-rise and civilian residential and other places of electricity.

    This device is suitable for GB/T14084.11 low voltage switchgear and control equipment – Part 6-1: multi – purpose electrical appliances switch electrical appliances

    HSQ6III-63 shell rack use category AC-33B, HSQ6III-100 shell rack and above.

    Use category for AC – 33 iB, level for PC

    DownloadHSQ6III series automatic transfer switch automatic switch
    • Product Detail
    • Parameters

    HSQ6III series automatic transfer switching equipment is a set of switches and logic control in one, without external controller, truly realize the integration of mechanical and electrical automatic switching device.with voltage detection, frequency detection, communication interface, electrical, mechanical interlock and other functions, It can realize automatic, electric remote, emergency manual control

    The operation of the motor is controlled by the logic control board with various logic commands,and gearbox operation to achieve,the electric motor with a switch spring saving energy,an instantaneous release acceleration mechanism,Fast through the breaker circuit or circuit switching.By the visible state to achieve security isolation it can greatly improve the electrical performance and mechanical performance of each phase

    HSQ6III series automatic transfer switch control part for metal shell, The switch part is made of glass fiber unsaturated polyester resin,which has strong dielectric property, protection ability and reliable operation safety

    Switch modeling is beautiful, novel, simple, small size, full function, is the best choice for similar products.

    Normal use, installation and transport conditions:

    The ambient air temperature is 5 ℃ ~ + 40 ℃.And the average value of 24 hours does not exceed +35℃

    The elevation must not be above 2000m

    Installation site of air relative humidity when the highest temperature is + 40 ℃ not more than 50%, at a lower temperature can have higher relative humidity, such as 20 ℃ at 90%.Due to temperature change occasionally produce condensation special measures should be taken, Installed in the absence of shock and vibration and place no snow or rain

    EMC class of equipment: B

    The product should be handled with care in the process of transportation, not upside down.

    Main technical performance parameters

    Rated current of shell frame level Inm(A) 63 100 160 250 630 1600
    Rated operating current Ie(A) 16.20.25.32.40.50.63 25.32.40.50.63.80.100 100.125.140.160 160.200.225.250 250.315.350.

    400.500.630

    800.1000.

    1250.1600

    Rated operating voltage Ue(V) 400/50Hz
    Rated insulation voltage level Ui(V) 800 690 1000
    Rated impulse withstand voltage Uimp(kV) 8 6 12
    Pole 2、3、4 3、4
    Use category AC-33B AC-33iB
    Rated short circuit current Iq(kA) 50kA 50kA 50kA 50kA 50kA 50kA
    Specification for short circuit protection appliances (SCPD) NT00-63A RT16-100A RT16-160A RT16-250A NGT3-630A STF5-1600A
    Operating transfer time (S) 3 3 1.5 1.5 1.5 1.5
    Rated control supply voltage Us(V)
    Operation cycle times No electricity 10000 8500 7000 7000 4000 3000
    Electric 6000 1500 1000 1000 1000 1000
    Total 16000 10000 8000 8000 5000 4000

    Controller function code

    Item ??note 1 A type controller B type controller
    A1(Power-grid) 2(Power-grid generator) B1(Power-grid) B2(Power-grid generator)
    Automatic conversion ??note 2 Automatic transfer and restoration ?Automatic transfer without restoration(As spare) Automatic transfer and restoration ?Automatic transfer without restoration(As spare)
    Detection of normal power supply Three phase detection of normal power supply
    Detection of standby power supply Three phase detection of standby power supply
    Mandatory conversion Mandatory normal、Mandatory standby、Mandatory disconnection
    Manual conversion Manual normal、Manual standby、Manual disconnection
    Power control ? ? ?Generator start and stop ? ? Generator start and stop
    Fire signal 24V fire signal to disconnect the device
    Fire feedback A set of normally open
    Communication function ?Note 3 (Optional communication module) Realization of remote control, telemetry, remote control, remote communication,RS485 interface, Modpus-RTU protocol,The communication baud rate ?1200、2400、9600、19200、38400bps
    Position indication Local position indication (The output of AC230, Used for normal and standby power switch to opening and closing )
    Feedback signal ? ? ? ? normal、standby under pressure feedback(Passive contact)

    normal、standby position feedback(Passive contact)

    normal、standby fault feedback(Passive contact)

    normal、standby under pressure feedback(Passive contact)

    normal、standby position feedback(Passive contact)

    normal、standby fault feedback(Passive contact) )

    Display mode ???Note 3 ?Mechanical indication:Device close break-brake state, operating modes(Factory settings, users can not modify)

    LCD:Device switching state ?normal、standby power status ??Parameter setting, action record, etc ( Split display )

    Under voltage detection The detection of arbitrary phase under undervoltage condition according to the undervoltage setting value
    Overvoltage detection Note 5 The detection of arbitrary phase overvoltage condition according to the overvoltage setting value
    Voltage loss (open phase) detection The detection of arbitrary phase voltage loss condition according to the voltage loss setting value
    Parameter

    setting

    Note 4(Split display has this function)

    Under pressure setting (U1=164V) Over voltage setting(U2=264V) Voltage loss (≤70V) Conversion delay(t1=2s)Delay return(t2=2s) Oil engine start delay(t3=5s) ?Oil machine stop time delay(t4=60s)
    Note:
    1. HSQ6III-63 type can only be equipped with A type controller ( temporarily does not have the function of 3, 4, 5 )
    2. The default factory value is set to automatic transfer and restoration, if the need for automatic transfer without restoration need to indicate when you order it
    3. This function is optional features, to be selected,the need for additional instructions.
    4. Default factory setting value

    Related Products

    HSM1z Series Moulded Case Circuit Breaker
    HSM1z series moulded case circuit breaker is competently applied in AC 50Hz electrical circuit with rated insulation voltage 800V, rated voltage up to 690V and rated current 40A(parameter setting 16A…
    More
    HSL1 Series Residual Current Circuit Breaker
    HSL1 series Residual Current Circuit Breaker is competently applied in AC 50Hz electrical circuit with rated insulation voltage 500V, rated voltage 400V and rated current 10A~ 800A for electric shock…
    More
    Power system switching device (type S)
    Power system conversion device (S) is to realize the two into line, one female united power conversion system between the device and its the executing circuit breaker, mechanical interlocking, controllers…
    More
    HSM8 series miniature circuit breaker
    HSM8 series miniature circuit breaker include HSM8-125, HSM8-100F, HSM8-63 HSM8N-32 and so on,Miniature circuit breaker is suitable for isolation, control, overload and short circuit protection of terminal distribution lines for…
    More
    • HangShen mobile website Latest news on mobile phone
    • HangShen wechat Scan with Wechat app
    • Products
      • Low-voltage distribution
      • Medium voltage distribution
      • Industrial control and protection
      • New energy
      • Complete sets of equipment
    • Download
      • Product sample
      • Manual of the modeling
      • Instruction book
      • Communication protocol
    • About Us
      • Brief introduction
      • “Hangshen” image
      • Technological innovation
      • Technical quality
      • Enterprise reputations
      • Enterprise culture
    • Contact Us
    Copyright 2016© HangShen Electric All Rights Reserved. ICP14040535-3
    Web Development by Anttoweb Web Design.
    WordPress Image Lightbox Plugin
    av大片_伊人网站_无码乱伦_一级爱爱片