      Home>>HSC1 series AC contactor
      • Complete sets of equipment
        • Low Voltage Complete-set Switchgear Equipment
        • High Voltage Complete-set Switchgear Equipment
        • Prefabricated substation
      • Low-voltage distribution
        • surge protector
        • automatic transfer switch automatic switch
        • Intelligent instrument
        • Intelligent Type Air Circuit Breaker
        • Moulded Case Circuit Breaker
          • Thermal Magnetic Moulded Case Circuit Breaker
          • Intelligent Type Moulded Case Circuit Breaker
          • Residual Current Circuit Breaker
        • Switch Disconnector
        • End Terminal Appliances
      • Medium voltage distribution
        • Vacuum circuit breaker
      • Industrial control and protection
        • AC contactor
        • motor protector
        • control and protection switch
        • series thermal overload Relay
      • New energy
      • Email hsdq@188.com
        • Technical 0571-82699110
        • Sales 0571-82699109
        • Service 0571-82600655

      HSC1 series AC contactor

      Description

      HSC1 series AC contactor is used in AC 50Hz, the main contact rated voltage to 690V, rated current 6.3A ~ 800A in the power system to connect and break circuit.It also can be combined with an appropriate electronic motor protector or a thermal overload relay to protect the electric circuit overload in the operation (running). ?The combination of the two contactors and the mechanical interlock can be used for the control of reversible or reverse braking motors and dual power supply control. ?products comply with IEC60947-4, GB14048.4 standards and obtain the national compulsory product certification “CCC” certificate.

      DownloadHSC1 series AC contactor
      • Product Detail
      • Parameters

      Installation site altitude not exceeding 2000m

      The upper limit of ambient temperature is +55 DEG C, the lower limit is -25

      The air relative humidity at the installation site shall be no more than 50% at the maximum temperature of +40 degrees celsius and can have a higher relative humidity at a lower temperature,for example air relative humidity can reach up to 90% under 20 degrees celsius.Special measures should be taken when changing temperature produces condensation.

      Installation site pollution level of 3

      The main circuit of the installation class is III, and the rest of the control and auxiliary circuits are Ⅱ

      Installation method : Vertical installation, Inclination of the mounting surface ≤±22.5°

      Table 1

      Model HSC1-6.3 HSC1-9M HSC1-9 HSC1-12 HSC1-16 HSC1-25 HSC1-32 HSC1-40
      Rated insulation voltage ?Ui V 690
      Rated heating Current ?Ith A 16 20 30 45
      Rated working Voltage Ue V 230??? 400??? 690
       

      Rated working current ??Ie ?A

       

      AC-3

      230V 6.3 9 9 12 16 25 32 40
      400V 6.3 9 9 12 16 25 32 40
      690V 3.5 6.9 6.9 9.1 12.5 12.5 22.1 22.1
       

      AC-4

      230V 5 6.3 6.3 9 12 16 25 32
      400V 5 6.3 6.3 9 12 16 25 32
      690V 2.8 5 5 6.7 8.9 8.9 17.8 17.8
      Control motor power

      Kw ?AC-3

      230V 1.7 2.2 2.2 3.0 4.0 6.1 8.5 11
      400V 3.0 4.0 4.0 5.5 7.5 11 15 18.5
      690V 3.0 5.5 5.5 7.5 11 11 18.5 18.5
      mechanical endurance Million times 1000
      Long-life electrical ???????AC-3

      Million times ???AC-4

      100

      5

      Million times ????AC-3

      次/h ????????AC-4

      No load

      800

      250

      7000

       

      Operating

      Rated voltage Us 36V??? 110V?? 127V?? 230V?? 400V
      Start power consumption ?VA 32 70 102 120
      Holding power consumption ?VA 5 8 12 15
      Energy efficiency grade 3 3 3 3
       

      Top mounted auxiliary contact

      Model ? ? Form

      CA122???? 2NO2NC

      CA131???? 3NO1NC

      CA140???? 4NO

      Model ? ? Form

      CA222???? 2NO2NC

      CA231???? 3NO1NC

      CA240???? 4NO

      Side mounted auxiliary contact – Model:CA411

      Form:1NO1NC

       

      Delay module (Top mounting)

      Delay on  

       

      –

      Model:TE1-3??? TE1-30?? TE1-180

      Delay range:0.1~3s? 1~30s?? 10~180s

      Delay off Model:TE2-3??? TE2-30?? TE2-180Delay range

      Delay range:0.1~3s? 1~30s?? 10~180s

      Communication interface module –
      ?Surge suppression module –
      ?Surge suppression module – ML1

      continued Table 1

      Model HSC1-50 HSC1-63 HSC1-75 HSC1-95 HSC1-110 HSC1-140 HSC1-170 HSC1-205
      Rated insulation voltage ?Ui V 690
      Rated heating current Ith A 70 95 140 205
      Rated heating current Ith A 230??? 400??? 690
       

      Rated working current

      Ie

      A

       

      AC-3

      230V 50 63 75 95 110 140 170 205
      400V 50 63 75 95 110 140 170 205
      690V 34.6 34.6 61 61 110 118 170 170
       

      AC-4

      230V 40 50 63 75 90 110 140 170
      400V 40 50 63 75 90 110 140 170
      690V 25 25 52.8 52.8 60 95 100 122
      Control motor

      Power

      Kw ?AC-3

      230V 15 18.5 22 22 37 45 55 64
      400V 22 30 37 45 55 75 90 110
      690V 30 30 55 55 75 110 156 156
      mechanical endurance ????Million times 1000
      mechanical endurance ????Million times ??????AC-3

      Million times ???????AC-4

      100

      5

      Million times ????AC-3 times/h ????????AC-4

      No load

      800

      250

      7000

      800

      250

      5000

      750

      250

      5000

      700

      200

      5000

      500

      130

      5000

       

      Operating coil

      Rated voltage Us 36V??? 110V?? 127V?? 230V?? 400V
      Start power consumption ?VA 190 275 387 906
      Holding power consumption VA 20.5 30 33 4.0
      Energy efficiency grade 2 2 2 2
       

      Top mounted auxiliary contact

      Model ? ?Form

      CA322???? 2NO2NC

      CA331???? 3NO1NC

      CA340???? 4NO

       

      –

      Side mounted auxiliary contact Model:CA511? CA520? CA502 ? Form:1NO1NC?? 2NO?? 2NC
       

      Delay module (Top mounting )

      Delay on  

      –

      Model:TE1-3??? TE1-30?? TE1-180

      Delay range:0.1~3s? 1~30s?? 10~180s

       

      –

      Delay off Model:TE2-3??? TE2-30?? TE2-180

      Delay range:0.1~3s? 1~30s?? 10~180s

      Communication interface module TX1
      Surge suppression module RC1
      ?Mechanical locking module ML1 –

      continued Table 1

      Model HSC1-250 HSC1-300 HSC1-400 HSC1-475 HSC1-630 HSC1-800
      Rated insulation voltage Ui V 690
      Rated heating current Ith A 300 400 475 630 800
      Rated working voltage ?Ue V ????????????????? 230??? 400??? 690
       

      Rated working current

      Ie

      A

       

      AC-3

      230V 250 300 400 475 630 800
      400V 250 300 400 475 630 800
      690V 205 250 300 400 630 800
       

      AC-4

      230V 205 250 300 300 570 570
      400V 205 250 300 270 520 520
      690V 160 160 190 190 362 362
      Control motor

      power

      Kw ?AC-3

      230V 78 93 125 145 191 250
      400V 132 160 200 250 335 450
      690V 190 235 275 375 573 750
      mechanical endurance ????Million times 600
      Long-life electrical ???AC-3

      Million times ????????AC-4

      60

      5

      Operating frequency ????AC-3

      次/h ????????AC-4

      No load

      700

      200

      3000

      500

      130

      3000

      500

      150

      2000

      400

      150

      2000

      500

      150

      1000

       

      Operating coil

      Million times Us 36V??? 110V?? 127V?? 230V?? 400V
      Start power consumption

      VA

      906 620 1018
      Holding

      power consumption VA

      4.0 11 14
      Energy efficiency grade 2 2 2 –
      Top mounted auxiliary contact ??????????????????????????? –
      Side mounted auxiliary contact Model:CA511? CA520? CA502 ? Form:1NO1NC?? 2NO?? 2NC
       

      Delay module

      (Top mounting)

      Delay on  

       

      –

      Delay off
      Communication interface module TX1
      Surge suppression module RC1
      Mechanical locking module –
      notes:
      1. HSC1-6.3 ~ 12 also can provide the four poles
      2. Mechanical locking module does not separate supply and must be matched with the contactor. When not specified, auxiliary contacts with 1 open and 1 closed
      3. GB21518 suitable 《 AC contactor energy efficiency limit value and energy efficiency grade 》 for rated operating current 6A ~ 630A AC contactor
      4. The reversible AC contactor has the same parameters as the standard

      Table 2

      Table 2 HSC1-25C HSC1-40C HSC1-63C HSC1-95C
      Rated insulation voltage Ui 690V
      Rated heating current ?Ith 30A 45A 70A 95A
      Rated working voltage ??Ue 230V?? 400V
      Rated working current ??Ie 230V 25 40 63 95
      400V 25 40 63 95
      AC-6b

      Rated control capacity kvar

      230V 10 15 25 35
      400V 15 30 45 60
      Surge suppression capability ≤20Ie
      mechanical endurance ???????Million times 100
      AC-6b Long-life electrical ???Million times 10
      Operating frequency ?????????times/h 240 120
      Operating coil characteristics and power consumption AC contactor with HSC1 serie
       

      Auxiliary contact ?( Side loading )

      Factory configuration:CA411??? 1只

      Optional installation :CA411??? 1只

       

      Factory configuration:CA511????? 1只

      Optional installation ?:CA511 or CA52 or ????????????CA502 ????1只

      Equipped with a fuse model RT16-50 RT16-63 RT16-125 RT16-160

      Related Products

      HSC2 series AC contactor
      HSC2 series AC contactor (hereinafter referred to as the contactor) for AC 50Hz, voltage 400V, current to 95A, for long-distance making and breaking circuit and frequent starting and control of…
      More
      HSJR1 series thermal overload Relay
      The series thermal relay has three shell frame of 25A、36A、93A, current specification 1A~93A. A full range of thermal relay can be installed vertically. After installation, the slope does not exceed…
      More
      HSD2 series electronic motor protector
      HSD2 series intelligent motor protector (hereinafter referred to as protector) has protection function of overload,phase failure,unbalance,under load, grounding protection , stall ,blocking, starting overtime, temperature (PTC), over voltage, under voltage,…
      More
      HSD1 series electronic motor protector
      HSD1 series of electronic motor protector (hereinafter referred to as protector) is suitable for AC 50Hz, rated voltage to 400V, rated current 0.5A ~ 300A single AC asynchronous motor circuit…
      More
      • HangShen mobile website Latest news on mobile phone
      • HangShen wechat Scan with Wechat app
      • Products
        • Low-voltage distribution
        • Medium voltage distribution
        • Industrial control and protection
        • New energy
        • Complete sets of equipment
      • Download
        • Product sample
        • Manual of the modeling
        • Instruction book
        • Communication protocol
      • About Us
        • Brief introduction
        • “Hangshen” image
        • Technological innovation
        • Technical quality
        • Enterprise reputations
        • Enterprise culture
      • Contact Us
      Copyright 2016© HangShen Electric All Rights Reserved. ICP14040535-3
      Web Development by Anttoweb Web Design.
      WordPress Image Lightbox Plugin