• <input id="mw26l"><button id="mw26l"></button></input>
  • <object id="mw26l"></object>

    • Emailhsdq@188.com
    • Phone0571-82699352
    • 中文
    Menu
    • Home
    • Products
      • Low-voltage distribution
      • Medium voltage distribution
      • Industrial control and protection
      • New energy
      • Complete sets of equipment
    • Download
      • Product sample
      • Manual of the modeling
      • Instruction book
      • Communication protocol
    • About Us
      • Brief introduction
      • “Hangshen” image
      • Technological innovation
      • Technical quality
      • Enterprise reputations
      • Enterprise culture
    • Contact Us

    Products

    Home>>HSC2 series AC contactor
    • Low-voltage distribution
      • Intelligent instrument
      • Intelligent Type Air Circuit Breaker
      • Moulded Case Circuit Breaker
        • Thermal Magnetic Moulded Case Circuit Breaker
        • Intelligent Type Moulded Case Circuit Breaker
        • Residual Current Circuit Breaker
      • Switch Disconnector
      • End Terminal Appliances
      • surge protector
      • automatic transfer switch automatic switch
    • Medium voltage distribution
      • Vacuum circuit breaker
    • Industrial control and protection
      • AC contactor
      • motor protector
      • control and protection switch
      • series thermal overload Relay
    • New energy
    • Complete sets of equipment
      • Low Voltage Complete-set Switchgear Equipment
      • High Voltage Complete-set Switchgear Equipment
      • Prefabricated substation
    • Email hsdq@188.com
      • Technical 0571-82699110
      • Sales 0571-82699109
      • Service 0571-82600655

    HSC2 series AC contactor

    Description

    HSC2 series AC contactor (hereinafter referred to as the contactor) for AC 50Hz, voltage 400V, current to 95A, for long-distance making and breaking circuit and frequent starting and control of AC motor, contactor auxiliary contact accessories.products comply with IEC60947-4, GB14048.4 standards and obtain the national compulsory product certification “CCC” certificate.

    DownloadHSC2 series AC contactor
    • Product Detail
    • Parameters

    Installation site altitude not exceeding 2000m

    The upper limit of ambient temperature is +55 DEG C, the lower limit is -25

    The air relative humidity at the installation site shall be no more than 50% at the maximum temperature of +40 degrees celsius and can have a higher relative humidity at a lower temperature,for example air relative humidity can reach up to 90% under 20 degrees celsius.Special measures should be taken when changing temperature produces condensation.

    Installation site pollution level of 3

    The main circuit of the installation class is III, and the rest of the control and auxiliary circuits are Ⅱ

    Installation method : Vertical installation, Inclination of the mounting surface ≤±5°

    Current specifications (A) 9 12 18 25 32 40 50 65 80 95
    Rated insulation voltage Ui(V) 500V
    Rated heating current Ith (A) 25 25 32 40 50 60 80 80 125 125
    Rated working voltage Ue(V) 400V
    Rated working current Ie (A) AC-3 400V 9 12 18 25 32 40 50 65 80 95
    Control motor power kW AC-3 400V 4 5.5 7.5 11 15 18.5 22 30 37 45
    mechanical endurance Million times 1000
    Long-life electrical Million times AC-3 10
    Operating frequency times/h AC-3 1200
    times 7000 5000
    Operating coil Rated control supply voltage Us 230V??? ???400V
    Start power consumption VA 70 70 110 110 110 200 200 200 200 200
    Holding power consumption VA 8 8 9 11 11 18 20 20 20 20
    Energy efficiency grade 3 3 3 3 3 2 2 2 2 2
    Arcing distance(mm) ≤10mm
    Side mounted (right) auxiliary contact ( Ontology configuration ) Model: 10? Form:1NO

    01? Form:1NC

    Model:11

    Form:1NO1NC

    Top mounted auxiliary contact module ( Matching ) Model:F4-04; F4-40;? F4-13;? F4-31; F4-02; F4-20; F4-22; F4-11

    Form:4NC;?? 4NO;??? 1NO3NC; 3NO1NC; 2NC;? 2NO;?? 2NO2NC; 1NO1NC

    notes : 1.Auxiliary contact: Ith=10A;Ui=500V; AC-15: AC400V/0.95A Recommended for use SCPD with RT16-00 (NT00) /16

    2、The side mounted auxiliary contact is integrated with the machine, factory configuration , 32A and the following table type selection (10 or 01), 40A and above specifications do not choose when ordering. Side mounted auxiliary can not be equipped with additional .

    3、Top mounted auxiliary for the selection of accessories , The number of each contactor installation is 1 , Indicate when ordering

    Related Products

    HSK6-63 control and protection switch
    HSK6-63 control and protection switch,It is mainly used for ac 50 hz, rated voltage 400 v, subjects rated current to 63 a, electronic tripping device is adjustable rated current 1A…
    More
    HSC1 series AC contactor
    HSC1 series AC contactor is used in AC 50Hz, the main contact rated voltage to 690V, rated current 6.3A ~ 800A in the power system to connect and break circuit.It…
    More
    HSD1 series electronic motor protector
    HSD1 series of electronic motor protector (hereinafter referred to as protector) is suitable for AC 50Hz, rated voltage to 400V, rated current 0.5A ~ 300A single AC asynchronous motor circuit…
    More
    HSJR1 series thermal overload Relay
    The series thermal relay has three shell frame of 25A、36A、93A, current specification 1A~93A. A full range of thermal relay can be installed vertically. After installation, the slope does not exceed…
    More
    • HangShen mobile website Latest news on mobile phone
    • HangShen wechat Scan with Wechat app
    • Products
      • Low-voltage distribution
      • Medium voltage distribution
      • Industrial control and protection
      • New energy
      • Complete sets of equipment
    • Download
      • Product sample
      • Manual of the modeling
      • Instruction book
      • Communication protocol
    • About Us
      • Brief introduction
      • “Hangshen” image
      • Technological innovation
      • Technical quality
      • Enterprise reputations
      • Enterprise culture
    • Contact Us
    Copyright 2016© HangShen Electric All Rights Reserved. ICP14040535-3
    Web Development by Anttoweb Web Design.
    WordPress Image Lightbox Plugin
    av大片_伊人网站_无码乱伦_一级爱爱片